FLP UNIVERSAL INDICATOR
♦ μP Based Power, full & highly reliable controller.
♦ Universal Input (RTD, t/c, 4-20 mA, 0-10 VDC).
♦ Transmitter loop power supply with current limit as standard.
♦ Retransmission 4-20 Ma and transmitter power supply.
♦ Flame proof low cost and compact size controller.
♦ I, IIA, IIB, IIC, IP 65 as per IS 2148/1981, certified by C.M.R.I., CCOE.
♦ Flame proof low cost and compact size controller.
♦ µP Based Power, full & highly reliable controller.
♦ I, IIA,IIB, IP 65 as per IS 2148/1981,certified by C.M.R.I.
♦ Universal Input T/C, RTD, Linear input selection.
♦ Potential Free Relay contact output upto ½/3/4.
♦ 0.1% Accuracy of FSD.
♦ Isolated 0/4-20mA process value retransmission output.
♦ All Configurations and calibration from front panel keypad.
♦ Highly communicative serial interface facility (RS 232/485).
♦ Transmitter loop power supply with current limit as standard.
♦ Power supply :230V/110V AC or 24V/12V DC
♦ Optional GSM mobile connectivity.
♦ Fully Password Protected Operation.
T/C - K, J, R, S, E, N, T
RTD -Pt-100, Cu53 ( 2wire & 3 wire)
Current -0 ~ 20mA DC, 4~20mA DC
Voltage -0-5V/1-5V, 0.5 -2.5V/0- 10 V DC
Special on demand -0-75/200 mV & 0-1/10V/100/300 V DC,0-75/200 mV 0-100/300V DC
Resistence - 0-500 R , 0-1/5/10 K, 1M
Transmitter power supply - 24V/5V DC @ 30 mA max, isolated from I/P & O/P
Cold junction comp. & Sensor break ind - Software base Automatic
Range limits - As per input range Table
Accuracy - +/- 0.1 % of span for linear & RTD, +/-0.25 % for T/C
Input impedance ->330 K for Voltage ,mV, and T/C, 100 R for current
Indication -Ut101- 4 digit 7 segment display.
Status indication -LEDs for Relay status & Communication.
Alarm modes -LowHigh.
On Off control - Dead Band controls
Dead Band controls -High and Low Set point for level application
Relay Output -Retransmission Current & Voltage outputs,1 Relays / SSR output
SSR Output -24VDC @ 20 mA ,12VDC @ 20 mA
Retransmission Current & Voltage outputs -0~20/ 4~20 mA, 0~5V, 0~10V, 1~5V DC, fully 3 port isolated
Communication Protocol -Modbus RTU RS- 485 Isolated communications.
Programmable parameter -Baud rate , Parity , Node address , stop bit.
Set point / High scale / Low scale -Full range as per input selection.
Relay logic -F.S. high & low alarm
Display resolution --1999 to 9999 fully configurable
Programming of parameters -Through 4 tactile keys
Dimensions & Mounting -As per box selection & wall/structure 2/2 holes.
(A) Supply voltage (B) Power consumption -(A) 110/230 V AC, 50/60 Hz (B) 4 watts maximum
Operating ambient Temperature and Humidity -0~50 °C Below 90%, non condensing
Gas group -I IIA IIB as per IS 2148/1981
Enclose certification -Enclosure is certifies by C.M.R.I. Dhanbad
Display glass -Clear glass thognet type A as per Is 2206
Degree protection -IP 65 as per IS 2147
Material of constructions -Aluminum alloy
Cable entry -5 x 3/4 “ ET