FLOW RATE TOTALISER

UT-1206

  • BATCH CONTROLLER

     

    ♦ Accept hi accurate universal inputs 4-20 mA or 0-10 VDC or pulse(2 or 3 wire).

    ♦ Maximum 4 C/O on batch values Generated.

    ♦ 5 digit flow rate and 10 digit total.

    ♦ Liner or Square root selections with 0.1% accuracy.

    ♦ All Standard batch fuctions included Like Start Stop and Pause.

    ♦ GSM mobile connectivity for wireless remote reading purpose(SMS).

  •  FEATURE

     

    ♦ Maximum 4 C/O on Batch values generated.

    ♦ Micro controller Based Powerful & highly reliable controller.

    ♦ 4-20 mA or 0-10 v or pulse (3 & 2 wire) input type.

    ♦ Potential Free Relay contact output 2 x flow and 2 x Totaliser.

    ♦ Liner or square root input selections with 0.1% Accuracy.

    ♦ Isolated 0/4-20mA retransmission output.

    ♦ All standard Batch Functions included.

    ♦ Highly communicative serial interface facility (RS 232/485).

    ♦ 24 v loop power supply for flow Transmitter

    ♦ 8/10 digit Flow Totaliser with password protected resetting.

    ♦ Various Enclosures supported Weather proof or flame proof.

    ♦ User friendly menu for device configurations & calibration.

    ♦ Field Configurable flow range. sort key function for batch Start, Stop and Pause.

    ♦ Flow and Batch computer software available.

    ♦ Optional GSM mobile connectivity for remote data reading and logging Through SMS.

► Input

Current - 0 ~ 20 mA dc , 4~20 mA DC

Voltage - 0-5V/1-5V, 0.5 -2.5V/0- 10 V DC

Pulse - PNP / NPN / 2 wire namur type

Transmitter power supply - 24 V DC @ 30 mA max, isolated from I/p & O/P

Range limits - 0.1 to 99999 Programmable with decimal point selection

Accuracy - +/- 0.1 % of span

Input impedance - >330 K for Voltage & 100 R for current.

Input mode - Linear or square root

► Indication

Indication -LCD TYPE : 5 digit Flow rate & 8 digit Totaliser-7 segment led display.

LCD TYPE - 5 digit Flow rate & 10 digit Totaliser-16x2 line back lite

Status indication - LEDs for Relay status & Communications

Alarm modes - Very Low / Low / High / very High

► CONTROL MODE

Batch Values - 2 ( Can be set in VALUE or % )

► Output

Relay Output -NO - C - NC Contacts , 5A@240 V AC Resistive

1 / 2 / 3 / 4 Relays

Retransmission Current & Voltage outputs - 0-20 mA/4-20 mA/0-10 v dc/0-5 v dc, fully 3 port isolated

Wireless communication - GSM/GPRS base mobile (sms) communication

► Communication

Communication Protocol & Connectable number -GSM/GPRS base mobile(sms) communications.

Programmable parameter & Connectable number -Baud rate, Parity, Node address, Stop bit & 0-256 unit.

Wireless communication -GSM / GPRS base mobile (sms) communication

► PROGRAMMBALE PARAMETERS

Relay logic -F.S. high & low potential free contact

Display resolution -- 0 to 99999 fully configurable for linear input

Programming of parameters -Through 4 tactile keys

► Other

(A) Dimensions (B) Panel cutout (C) Mounting - (A) 96(H) x 96(W) x 100(D) (B) 92 x 92 (C) panel mounted

(A) Supply voltage (B) Power consumption -(A) 110/230 V AC, 50/60 Hz (B) 4 watt maximum

Operating ambient temperature and humidity - • 0~50 °C • Below 90%, non condensing

► Flame Proof

Gas group - I IIA IIB as per IS 2148/1981

Enclose certification - Enclosure is certifies by C.M.R.I. Dhanbad

Display glass - Clear glass thognet type A as per IS 2206

Degree protection - IP 65 as per IS 2147

Material of constructions -Aluminum alloy

Cable entry -5 x 3/4 “ ET

External keys -4 nos push button