CLEAN ROOM / PHARMA INDICATORS

UT-1407

  • TEMP+RH+DP+TIME INDICATOR

     

    ♦ USFD 21 CFR part 11 & GMP-4 compatible.

    ♦ Indicator with inbuilt T+RH+DP+Time measurement in single enclosure.

    ♦ Incorporates highly stable built-in or Remote Temp.+ RH+DP sensor.

    ♦ The Synchronised clocks slave clock for GPS or SERVER Time indication.

    ♦ Built in Real Time Clock.

    ♦ Inbuilt buzzer to audible process value violation.

    ♦ Compact all Stainless Steel enclosure with 35mm depth.

  •  FEATURE

     

    ♦ FDA 21 CFR part 11 - GAMP-4 compatible.

    ♦ Micro controller based indicator with inbuilt Temp+RH+DP+Time measurement in single enclosure.

    ♦ All channel are programmable ranges and unit.(Through Front key pad).

    ♦ Incorporates highly stable built-in Pressure Sensor and Temp.+ RH sensor.

    ♦ 3 Digit, 0.56" bright LED display for displaying DP, RH & Temperature and 4 digit for time.

    ♦ Process parameter Hi and Low LEDs. Status indication For All three channel.

    ♦ User selectable set limits for process value violation.

    ♦ MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA, etc.

    ♦ Compact, All Stainless Steel enclosure with 35 mm depth for installation in prefab panels.

    ♦ Inbuilt buzzer to audible process value violation.

    ♦ Password protection for calibration and programming mode.

    ♦ Software Calibration for 3 channels.

    ♦ Programmable devise address, baud rate, parity and stop bit.

    ♦ Remote programmable from master device.

    ♦ User programmable offset correction.

    ♦ Brick and modular wall mounting and flush mounting.

    ♦ FDA21 CFR part 11 compliance data logging software available

    ♦ Time is continusly syncronized with system

► Input

Nos. of input - 4 nos .(TEMP + RH + DP+TIME)

Temperature input - Integral Or Remote (external)

Humidity input - Integral Or Remote (external)

DP input - Integral Or Remote (external)

Transmitter power supply - 24V/5V DC @ 30 mA max, isolated from I/P & O/P

► Indication

Temperatures -Channel-1 : 3 digit Seven segments 0.56” RED display.

Humidity -Channel-2 : 3 digit Seven segments 0.56” RED display.

DP -Channel-3 : 3 digit Seven segments 0.56” RED display.

TIME -Channel-4 : 4 digit Seven segments 0.56” RED display.(HH:MM)

Status indication -6-LEDs for visual alarms, buzzer for audible alarm, LED for 485-comm.

► Range

Temperatures -0 to 60.0 *C with decimal point.

Humidity -0 to 100 % with decimal point.

DP - -10 to 10 mm / -25 to 25mm / -100-100 mm /-200 to 200 mm wc

Time - hour : minuets 12 or 24 hour formats 00:00

Display Resolution - 0.1 for Temp. & Rh For DP mm wc : 0.1 / PA : 1 / Hpa :0.01

► Accuracy

Temperatures - 0.25 % on FS Response time : 8 sec

Humidity - 2.5 % for 10 to 90 % RH rest of 3% Response time : 4 sec

DP -1 % on FS in all unit Response time : 1 sec

Time - 0.01 % Response time : 1 sec

► Communication

Communication Protocol -Modbus RTU RS- 485 Isolated communications.

Programmable parameter -Baud rate , Parity , Node address , stop bit.

Read /write parameter -Read: Process value ,decimal point. Write: Hi Low set point.

No. of slave ID -Total 1-256 unit.

► Parameters

Set point / High scale / Low scale -Full range as per input selection.

Programming of parameters -Through 4 tactile keys (with password protections)

Alarm logic -Full Scale HI OR Full scale Low

► Other

Mounting -Bricks and modules wall Flush panel mounting.

MOC -Full S S 316 plate and box , back side wall mounting M S covers.

Supply voltage Power consumption -24 v DC @ 4 watts maximum

Operating ambient temperature and humidity - - 0~50 °C - Below 90%, non condensing