FLP INSTRUMENT

UT-30XX-F

  • FLP MULTI CHANNEL INDICATOR

     

    ♦ I, IIA, IIB, IIC, IP 65 as per IS 2148/1981, certified by C.M.R.I., CCOE.

    ♦ Low cost and compact FLP housing at best reliability.

    ♦ Universal input (RTD,t/c,4-20 mA,0-10 VDC).

    ♦ 4/8/12/16/20/24 channel Indicators available.

    ♦ All channel are fully isolated with transmitter power suppy.

  •  FEATURE

     

    ♦ Flame proof low cost and compact size controller.

    ♦ µP Based Power, full & highly reliable controller.

    ♦ I, IIA, IIB, IP 65 as per IS 2148/1981, certified by C.M.R.I.

    ♦ 4/8 nos. Universal Input T/C, RTD, linear input selection.

    ♦ 0.1% Accuracy of FSD.

    ♦ All Configurations and calibration from front panel keypad.

    ♦ High speed communicative serial (RS 232/485) interface.

    ♦ Transmitter loop power supply with current limit as standard.

    ♦ Power supply : 230V/110V AC or 24V/12V DC

    ♦ Fully Password Protected Operation.

► Input

T/C - K, J, R, S, E, N, T

RTD -Pt-100, Cu53 ( 2wire & 3 wire)

Current -0 ~ 20mA DC, 4~20mA DC

Voltage -0-5V/1-5V, 0.5 -2.5V/0- 10 V DC

Special on demand -0-75/200 mV & 0-1/10V/100/300 V DC,0-75/200 mV 0-100/300V DC

Resistence - 0-500 R , 0-1/5/10 K, 1M

Transmitter power supply - 24V/5V DC @ 30 mA max, isolated from I/P & O/P

Cold junction comp. & Sensor break ind - Software base Automatic

Range limits - As per input range Table

Accuracy - +/- 0.1 % of span for linear & RTD, +/-0.25 % for T/C

Input impedance ->330 K for Voltage ,mV, and T/C, 100 R for current

► Indication

Indication -4 Digit process value 7 segment display.

Status indication -LEDs for High & Low alarm status & communicaton.

Alarm modes -LowHigh.

► CONTROL MODE

On Off control - Dead Band controls

Dead Band controls -High and Low Set point for level application

► OUTPUT

Relay Output -Retransmission Current & Voltage outputs,1 Relays / SSR output

SSR Output -24VDC @ 20 mA ,12VDC @ 20 mA

Retransmission Current & Voltage outputs -0~20/ 4~20 mA, 0~5V, 0~10V, 1~5V DC, fully 3 port isolated

► Communication

Communication Protocol -Modbus RTU RS- 485 Isolated communications.

Programmable parameter -Baud rate , Parity , Node address , stop bit.

► Parameters

Set point / High scale / Low scale -Full range as per input selection.

Relay logic -F.S. high & low alarm

Display resolution --1999 to 9999 fully configurable

Programming of parameters -Through 4 tactile keys

► Other

Dimensions & Mounting -As per box selection & wall/structure 2/2 holes.

(A) Supply voltage (B) Power consumption -(A) 110/230 V AC, 50/60 Hz (B) 4 watts maximum

Operating ambient Temperature and Humidity -0~50 °C Below 90%, non condensing

► Flame Proof

Gas group -I IIA IIB as per IS 2148/1981

Enclose certification -Enclosure is certifies by C.M.R.I. Dhanbad

Display glass -Clear glass thognet type A as per Is 2206

Degree protection -IP 65 as per IS 2147

Material of constructions -Aluminum alloy

Cable entry -5 x 3/4 “ ET